On-Gird Inverter
R1 Mini
1.6kW / 2.7kW / 3.3kW | Single Phase, 1 MPPT
RENAC R1 Mini Series inverter is an ideal choice for residential projects with higher power density,wider input voltage range for more flexible installation and a perfect match for high power PV modules.
-
16A
Max. PV
input current
-
AFCI
Optional AFCI
protection function
-
150%
150% PV
input oversizing
Product Features
Export control function integrated
Over-temperature protection
Type II SPD for both DC and AC
Remote firmware upgrade & setting

Parameter List
| Model | R1-1K6 | R1-2K7 | R1-3K3 |
| Max. PV Input Voltage[V] | 500 | 550 | |
| Max. PV Input Current [A] | 18 | ||
| No.of MPPT Trackers/No.of Input Strings per Tracker | 1/1 | ||
| Max. AC Output Apparent Power [VA] | 1600 | 2700 | 3300 |
| Max.Efficiency | 97.5% | 97.6% | 97.6% |
Related Products
On-Gird Inverter
1.6kW / 2.7kW / 3.3kW | Single Phase, 1 MPPT
RENAC R1 Mini Series inverter is an ideal choice for residential projects with higher power density,wider input voltage range for more flexible installation and a perfect match for high power PV modules.
Download More
Product Video

Related FAQs
Cause of occurrence:
PV input voltage is an overrating or inverter hardware issue.
Solution:
(1) Check the PV configuration to see if there are too many solar panels connected to a system that caused the PV input voltage to be over rating, if so, please reduce the solar panels.
(2) Disconnect the PV and AC connections to completely shut off power to the inverter. Wait for 5 minutes before reconnecting and powering on.
(3) If the problem persists, please contact your installer or service provider.
Cause of occurrence:
The power supply automatically shuts off due to excessive current above the set standard.
Solution:
(1) Disconnect the PV and AC connections to completely shut off power to the inverter. Wait for 5 minutes before reconnecting and powering on.
(2) Check whether the PV, AC, and grounding lines are damaged or loosely connected, resulting in poor contact.
(3) If the problem persists, please contact your installer or service provider.
Cause of occurrence:
The bus voltage is above the standard set by the software.
Solution:
(1) To turn off the inverter, you should first switch off the DC and AC power sources, wait for 5 minutes, then connect them again and restart the inverter.
(2) If still have an error message, check if the DC/AC voltage exceeds the parameter specification requirements. If it does, improve it promptly.
(3) If the error persists, the hardware may be damaged. Please contact your installer or service provider.