R1 Mini

1.6kW / 2.7kW / 3.3kW | Single Phase, 1 MPPT

RENAC R1 Mini Series inverter is an ideal choice for residential projects with higher power density,wider input voltage range for more flexible installation and a perfect match for high power PV modules.

  •  
    16A

    Max. PV

    input current

  •  
    AFCI

    Optional AFCI

    protection function

  •  
    150%

    150% PV

    input oversizing

Product Features

  • ExportExport control function integrated
  • 特征图标-4Over-temperature protection
  • 特征图标-2Type II SPD for both DC and AC
  • 特征图标-3Remote firmware upgrade & setting
产品图 正

Parameter List

Model R1-1K6 R1-2K7 R1-3K3
Max. PV Input Voltage[V] 500 550
Max. PV Input Current [A] 18
No.of MPPT Trackers/No.of Input Strings per Tracker 1/1
Max. AC Output Apparent Power [VA] 1600 2700 3300
Max.Efficiency 97.5% 97.6% 97.6%

Related Products

On-Grid Inverter

On-Grid Inverter

3.68kW / 5kW / 6kW | Single Phase, 2 MPPTs

View More
On-Grid Inverter

On-Grid Inverter

8kW / 10kW | Single Phase, 2 MPPTS

View More
On-Grid Inverter

On-Grid Inverter

6kW / 8kW / 10kW / 12kW | Three Phase, 2 MPPTS

View More
On-Grid Inverter

On-Grid Inverter

15kW / 20kW / 25kW | Three Phase, 2 MPPTs

View More
On-Grid Inverter

On-Grid Inverter

30kW / 50kW | Three Phase, 3/4 MPPTs

View More
On-Grid Inverter

On-Grid Inverter

100kW-125kW | Three Phase, 9 MPPTs

View More
On-Gird Inverter

On-Gird Inverter

1.6kW / 2.7kW / 3.3kW | Single Phase, 1 MPPT

RENAC R1 Mini Series inverter is an ideal choice for residential projects with higher power density,wider input voltage range for more flexible installation and a perfect match for high power PV modules.

Download More

Product Video

Product introduction
Product installation

Related FAQs

  • "Bus unbalance"fault on inverter screen.

    Cause of occurrence:

    PV input voltage is an overrating or inverter hardware issue.

    Solution:

    (1) Check the PV configuration to see if there are too many solar panels connected to a system that caused the PV input voltage to be over rating, if so, please reduce the solar panels.

    (2) Disconnect the PV and AC connections to completely shut off power to the inverter. Wait for 5 minutes before reconnecting and powering on.

    (3) If the problem persists, please contact your installer or service provider.

  • "GFCI Fault" on inverter screen.

    Cause of occurrence:

    The power supply automatically shuts off due to excessive current above the set standard.

    Solution:

    (1) Disconnect the PV and AC connections to completely shut off power to the inverter. Wait for 5 minutes before reconnecting and powering on.

    (2) Check whether the PV, AC, and grounding lines are damaged or loosely connected, resulting in poor contact.

    (3) If the problem persists, please contact your installer or service provider.

  • "Bus voltage Fault" on inverter screen.

    Cause of occurrence:

    The bus voltage is above the standard set by the software. 

    Solution:

    (1) To turn off the inverter, you should first switch off the DC and AC power sources, wait for 5 minutes, then connect them again and restart the inverter.

    (2) If still have an error message, check if the DC/AC voltage exceeds the parameter specification requirements. If it does, improve it promptly. 

    (3) If the error persists, the hardware may be damaged. Please contact your installer or service provider.